For a Control Plan or an operation in the Control Plan, after generating Inspection Definitions from a part with product and manufacturing information (PMI), a quality engineer can compare the PMI in the revised part to the original imported PMI and choose to import the modified PMI. When a quality engineer clicks a single modified balloon or a row in the table, a table appears displaying the previous and revised values. As an administrator, you can configure which properties are used to define the uniqueness of characteristics, and these same properties are displayed in the comparison table too.

Procedure

  1. In Preferences, search for the ACP_IPXMLKEYS_TO_COMPARE_TWO_BALLOONS preference, select it from the search results, and click Edit .

  2. Add additional properties in this format:

CopyIpxmlKey:Internal Name of the Teamcenter property:Business Object Name

The following properties are available by default: CopyB2005:qc0Criticality:Qc0MasterCharSpec K2101:qc0NominalValue:Qc0VariableCharSpec K2112:qc0LowerTolerance:Qc0VariableCharSpec K2113:qc0UpperTolerance:Qc0VariableCharSpec K2892:qc0SingleLimit:Qc0VariableCharSpec